Regardless of your plumbing code the minimum drain size for a toilet is 3 inches.
Plumbing code floor drain required restroom.
Jump to full code chapter.
2014 fbc plumbing 5 th edition 4 fixtures faucets and fixture fittings 412 floor and trench drains 412 2 floor drains.
Floor drains shall have removable strainers.
In tenant spaces without access to a centrally located service sink and having limited areas of hard surface floors the required service sink may be omitted subject to the approval of the code enforcement official if at least one toilet room within the space is equipped with hose bib outlets for hot and cold water and a floor drain.
Some older model toilets flushing over 1 6 gallons per flush are rated at 4 dfus.
The floor drain shall be constructed so that the drain is capable of being cleaned.
If the insurance doesnt want to pay then they should lobby the code authorities to make them a requirement.
The floor trough drain shall incorporate removable strainers.
Floor trough drains shall have integral or separate traps providing a minimum water seal of three inches.
4 at least one floor drain shall be located in every restroom having a masonry or concrete floor except those for private use.
A dfu is the unit of probable discharge that a particular plumbing fixture produces.
The floor trough drain shall be constructed so that it can be readily cleaned and the drain inlet shall be easily accessible at all times.
Code for floor drains in commercial bathrooms author.
Wall hung fixtures shall be rigidly supported so that strain is not transmitted to the plumbing system.
Running a drain across a room that does not have a basement or crawlspace might call for careful calculations.
In most cases drainpipes must slope at least 1 4 inch per running foot.
5 in hospitals and nursing homes floor drains will not be required in toilet bath facilities serving four or fewer individual residents where access to the facilities is direct from no more than two resident rooms.
Floor drain requirement syarn structural 5 nov 08 10 10 lone star 2006 national standard plumbing code section 7 16 4 requires a floor drain in toilet rooms containing either two or more water closets or wall hung urinals or a combination of one or more water closets and wall hung urinals except in a dwelling unit outside of nj not certain what other states actually have adopted the nspc syarn.
Some codes allow level vents.
Floor outlet or floor mounted fixtures shall be secured to the drainage connection and to the floor where so designed by screws bolts washers nuts and similar fas tenersofcopper brassorothercorrosion resistantmaterial.
Codes might require that vent pipes slope 1 8 inch per foot.