This width may be increased based upon specific department operations and or apparatus.
Minimum gate width for fire truck.
Sliding swinging gates boom gates bollards vehicle security barriers must not make it difficult for appliances to gain access.
Water pump minimum water pump capacity.
Gates shall be of the swinging or sliding type.
Free and clear see attachment.
Measures to gain access.
This limit in nfpa 1 and the ifc is 150 feet for buildings without a complete sprinkler system.
At least 2 feet wider than fire lanes.
The minimum clear width of fire department access roads shall be 20 feet 6 096 mm.
Alternate designs may be approved on a case by case basis.
10 a fire apparatus access road sh all be a minimum unobstructed width of 20 for commercial structures or 4 or more parcels or building sites.
Where a single gate is provided the gate width shall be not less than 20 feet 6096 mm.
20 gpm for a 1 inch cafs discharge.
A list of local fire and rescue agencies is available from the county administrators office 540 473 8233.
Widths and clearances around the accessway minimum trafficable width of 3 5m and be substantially clear of encroachments for at least 0 5mon each side and clear of encroachments at least 4m vertically.
Where a fire apparatus road consists of a divided roadway the gate width shall be not less than 12 feet 3658 mm.
Even with a road this width no other vehicles can pass when a large fire truck is traveling the road.
A minimum width of 3 5 m and height of 4 m should be provided at site entrances internal entrances and between buildings.
Construction of an all weather surface.
75 000 pounds 34 050 kg or as otherwise determined by the fire code official.
Minimum standards for security gates gates shall not reduce the required roadway width to less than the minimum width required by the fire department 20 ft.
Accessway should be constructed of an all weather surface e g.
Adequate stacking lane shall be provided based on the projected volume of traffic for the project.
The access road may be reduced to 12 of unobstructed width with a minimum 10 wide driving surface for 1 3 parcels or building sites on approval of the fire marshal and plfr.
Minimum building access for fire apparatus is a function of the access road reaching to within a certain distance of all portions of the building s first floor exterior walls.
Perimeter security points e g.
A 20 foot width with hard shoulders.
In addition to the minimum standards and specifications for small brush trucks large brush trucks and tankers described above the following minimum standards are required for cafs equipped vehicles and slip on modules.